Description
DESCRIPTION
1. The double door structure adopts high quality glass, easy to observe samples, the outdoor with magnetic strip is easy to be opened and closed, good sealing, open door power-off function.
2. Standard lights, UV lamps, with breeze circulation fan.
3. High precision digital independent temperature limiter.
4.With function of cutting off UV lamp by open door.


Standard lights, UV lamps, with breeze circulation fan.

SPECIFICATIONS
| Model | ICB-45P | ICB-65P | ICB-125P | ICB-210P | |
| Cycle Mode | Breeze circulation | ||||
| Function | Tem. Range | RT+5~70℃ | |||
| Tem. Resolution Ratio | 0.1℃ | ||||
| Tem. Motion | ±0.5℃ | ||||
| Tem. Uniformity | ±0.8℃ | ||||
| Structure | Inner Chamber | Mirror stainless steel | |||
| Outer Shell | Cold rolling steel electrostatic spraying exterior | ||||
| Insulation layer | High quality foam board | ||||
| Heater | Mica electrothermal film | ||||
| Power Rating | 0.35kW | 0.45kW | 0.6kW | 0.7kW | |
| Exhaust hole | φ28mm top(with function of test hole) | ||||
| Controller | Tem. control mode | PID Intelligent | |||
| Tem. setting mode | Touch button setting | ||||
| Tem. display mode | Digital temperature: LCD upper row; Setting temperature: the lower row | ||||
| Timer | 0-9999 min (with timing wait function) | ||||
| Operation function | Fixed temperature operation,timing function, auto stop. | ||||
| Additional funciton | LED Floodlight, Sensor deviation correction Temperature overshoot self-tuning Power-off parameter memory | ||||
| Sensor | PT100 | ||||
| Safety device | Digitial, over temperature sound-light alarm | ||||
| Specification | Inner Chamber size(W*L*H)(mm) | 350*350*350 | 400*350*450 | 500*450*550 | 600*580*600 |
| Exterior size (W*L*H)(mm) | 525*480*620 | 575*480*720 | 675*580*820 | 775*710*870 | |
| Packing size (W*L*H)(mm) | 605*572*775 | 655*572*875 | 755*672*975 | 855*802*1025 | |
| Volume | 45L | 65L | 125L | 210L | |
| Shelf number | 7 | 9 | 13 | 14 | |
| Load per rack | 15kg | ||||
| Shelf space | 35mm | ||||
| Supply(50/60HZ)Current rating | AC220V/1.1A | AC220V/1.1A | AC220V/2.3A | AC220V/2.7A | |
| NW/GW (kg) | 27/30 | 32/35 | 45/49 | 58/63 | |
| Accessory | Shelf | 2 | |||
| Shelf frame | 4 | ||||
| Optional Accessories | Shelf, USB interface | ||||
-
商品Graphite Furnace System, GRD-3202
-
商品Biological Microscope, MSC-B103T(Sliding)
-
商品Low Speed Centrifuge, Benchtop, CFG-550
-
商品Semi-Auto Biochemistry Analyzer, BA-SA-100
-
商品Pressure Steam Sterilization Effect Monitoring Rapid Biological Test Kit,BIK-1S
-
商品Hydrostatic Balance, HB-K Series
-
商品Benchtop Freeze Dryer, LYO60B-1S
-
商品Illumination Chamber, ICB-L-E Series
-
商品Portable Incubator, ICB-P9
-
商品Shaking Incubator, ICB-S0420, ICB-S1020