  • Grating Spectrophotometer, SP-CLR606
  • Grating Spectrophotometer, SP-CLR606

  • 商品型號

  • 商品規格

    Wavelength Range: 360-780nm
    Wavelength Pitch: 10nm
    High configuration of hardware
    Double Array 256 Image Element CMOS Sensor

分享到

Description

1, High configuration of hardware: 7 inches TFT Color Capacitive Touch-screen Display; Bluetooth 2.1; Concave Grating.

2, Double Array 256 Image Element CMOS Sensor; Long life-span stable LED, UV LED.

3, With reflective and transmissive spectrum, and accurate Lab value, it is good to calculate color formula and do precise color transmission.

4, Auto identify measured aperture. Freely switchable between 4 measured apertures: φ25.4mm/15mm/8mm/4mm. Users also can customize apertures.

5, Built-in temperature sensor to monitor and compensate the measuried temperature to ensure the measurement more precision.

6, Wavelength range 360nm – 780nm. Built-in 400nm cut off/420nm cut off/460nm cut off (only xenon lamp edition), more professional in UV measurement.

7, Independent light source detector, can continuously monitor the condition of light sources to ensure the light source reliable.

8, Multiple measurement modes: Quality Management Mode, Sample Mode; Meet more users’ requirements.

9,A variety of optional accessories: Reflection sample holding tool, transmission fixture, micro 4mm aperture transmission test components, and instrument inversion test components, applicable to more working conditions;

10, Big capacity data storage, for 40000 pieces test result.

11, Built-in camera locating.

12, More powerful extended functions at the PC software.

Application Industry

SP-CLR606 benchtop spectrophotometer is used to do precise color analysis and transmission in laboratories. It can be widely applied in different industries, such as plastics, electronics, paint and ink, printing, garments, leather, paper, auto, medical, cosmetics, food, science institutes, and laboratories.

Specifications

ModelSP-CLR606
Optical GeometryReflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ;
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source
Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ;
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source;
Haze(ASTM D1003),
Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7
ApplicationIt is used for accurate analysis and transmission of laboratory color.It can be applied in paints, inks, textiles, garments, printing and dyeing, printing and other industries for color transfer and quality control.
Integrating Sphere SizeΦ154mm
Light Source360 nm to 780 nm, Combined LED Light, 400nm cut-off light source,420nmCut-off light source
Spectrophotometric ModeConcave Grating
Sensor256 Image Element Double Array CMOS Image Sensor
Wavelength Range360-780nm
Wavelength Interval10nm
Semiband Width5nm
Measured Reflectance Range0-200%
Measured ApertureReflective : Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive : Φ25.4mm;
Remark: 1. Automatic identification of switch caliber   2. Customized Configuration caliber and lens position
Specular ComponentReflectance: SCI&SCE  / Transmittance: SCI&SCE
Color SpaceCIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99
Color Difference FormulaΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter),
Other Colorimetric IndexWI (ASTM E313, CIE/ISO, AATCC, Hunter),
YI (ASTM D1925, ASTM 313),
TI (ASTM E313, CIE/ISO),
MI (Metamerism Index),
Staining Fastness, Color Fastness, Color Strength, Opacity,
8° Glossiness,Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003)Saybolt, Color Code (ASTM D1500)
Observer Angle2°/10°
IlluminantD65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30
Displayed DataSpectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset
Measurement TimeAbout 2.4s (Measure SCI & SCE about 5s)
RepeatabilitySpectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)                                                                                        Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Inter-instrument ErrorΦ25.4mm/SCI, Within ΔE*ab 0.12
 (Average for 12 BCRA Series II color tiles)
DimensionL*W*H=370x300x200mm
WeightApprox. 9.6kg
PowerAC 24V, 3A Power adapter power supply
Illuminant Life Span5 years, more than 3 million times measurements
Display7-inch TFT color LCD, Capacitive Touch Screen
Data PortUSB & Bluetooth & Print serial port
Data StorageStandard 5000 Pcs, Sample 40000 Pcs
LanguageSimplified Chinese, Traditional Chinese, English, (Optional Customized German, French and Spanish)
Operating Environment0~40℃, 0~85%RH (no condensing), Altitude < 2000m
Storage Environment-20~50℃, 0~85%RH (no condensing)
Standard AccessoryPower Adapter,Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber,Transmissive Test Component, Micro Aperture(4mm) transmission test clamp component
Optional AccessoryMicro Aperture(4mm) transmission test clamp component
Notes:The specifications are subject to change without notice.
 
 
沄權生物科技有限公司-實驗室耗材買賣,新竹實驗室耗材買賣,竹北實驗室耗材買賣,實驗室儀器設備,實驗室校正TAF
電話 : 0919055272

  • 服務項目

  • 特別關鍵字

    實驗室耗材,新竹實驗室耗材,竹北實驗室耗材,實驗室耗材買賣,新竹實驗室耗材買賣,竹北實驗室耗材買賣,實驗室器材買賣,新竹實驗室器材買賣,竹北實驗室器材買賣,實驗室耗材批發商,新竹實驗室耗材批發商,竹北實驗室耗材批發商,實驗室耗材供應商,新竹實驗室耗材供應商,竹北實驗室耗材供應商,實驗室耗材批發,新竹實驗室耗材批發,竹北實驗室耗材批發,生物耗材,新竹生物耗材,竹北生物耗材,生物耗材批發,新竹生物耗材批發,竹北生物耗材批發,生物耗材批發商,新竹生物耗材批發商,竹北生物耗材批發商,買生物耗材,新竹買生物耗材,竹北買生物耗材,細胞耗材,新竹細胞耗材,竹北細胞耗材,細胞耗材批發,新竹細胞耗材批發,竹北細胞耗材批發,細胞耗材批發商,新竹細胞耗材批發商,竹北細胞耗材批發商,細胞耗材買賣,新竹細胞耗材買賣,竹北細胞耗材買賣,TAF實驗室規劃,新竹TAF實驗室規劃,竹北TAF實驗室規劃,實驗室設備買賣,新竹實驗室設備買賣,竹北實驗室設備買賣,理化實驗設備,新竹理化實驗設備,竹北理化實驗設備,買理化實驗設備,新竹買理化實驗設備,竹北買理化實驗設備,實驗室設備代理商,新竹實驗室設備代理商,竹北實驗室設備代理商,實驗室設備維修,新竹實驗室設備維修,竹北實驗室設備維修,實驗室儀器買賣,新竹實驗室儀器買賣,竹北實驗室儀器買賣,實驗室儀器設備買賣,新竹實驗室儀器設備買賣,竹北實驗室儀器設備買賣,實驗室儀器維修,新竹實驗室儀器維修,竹北實驗室儀器維修,實驗室試劑買賣,新竹實驗室試劑買賣,竹北實驗室試劑買賣,生物試劑買賣,新竹生物試劑買賣,竹北生物試劑買賣,試劑公司,新竹試劑公司,竹北試劑公司,細胞培養試劑,新竹細胞培養試劑,竹北細胞培養試劑,蛋白質研究試劑,新竹蛋白質研究試劑,竹北蛋白質研究試劑,PCR試劑,新竹PCR試劑,竹北PCR試劑,實驗室儀器校正,新竹實驗室儀器校正,竹北實驗室儀器校正,超低溫冷凍櫃校正,新竹超低溫冷凍櫃校正,竹北超低溫冷凍櫃校正,培養箱校正,新竹培養箱校正,竹北培養箱校正,微量分注器校正,新竹微量分注器校正,竹北微量分注器校正,醫院實驗室耗材,新竹醫院實驗室耗材,竹北醫院實驗室耗材,醫院實驗室設備,新竹醫院實驗室設備,竹北醫院實驗室設備,學校實驗室耗材,新竹學校實驗室耗材,竹北學校實驗室耗材,學校實驗室設備,新竹學校實驗室設備,竹北學校實驗室設備,科研機構耗材供應,新竹科研機構耗材供應,竹北科研機構耗材供應,軍防單位耗材供應,新竹軍防單位耗材供應,竹北軍防單位耗材供應,細胞專用設備,新竹細胞專用設備,竹北細胞專用設備,微生物專用設備,新竹微生物專用設備,竹北微生物專用設備,蛋白質專用設備,新竹蛋白質專用設備,竹北蛋白質專用設備,廢溶液回收處理,新竹廢溶液回收處理,竹北廢溶液回收處理,廢溶液處理,新竹廢溶液處理,竹北廢溶液處理,廢液處理,新竹廢液處理,竹北廢液處理,實驗室排煙櫃訂製,新竹實驗室排煙櫃訂製,竹北實驗室排煙櫃訂製,